Fluke Calibration 9143-B-P-156 Dry-Well Field Calibrator, 115V with 9143-INSB
Dry-Well Field Calibrator, 115V with 9143-INSB & Built-in Elct

Order #: 9143-B-P

Mfg #: 3054607

Questions about availability or need help? Contact Us:

(800) 633-0561
$8,694.00

Fluke Calibration 9143-B-P-156 Dry-Well Field Calibrator, 115V with 9143-INSB

Dry-Well Field Calibrator, 115V with 9143-INSB & Built-in Elct

Order #: 9143-B-P

Mfg #: 3054607

$8,694.00
Availability: Ships in 3-4 weeks
This product is available for shipping to the United States, Canada, and Puerto Rico only.
This product is available for shipping to the United States, Canada, and Puerto Rico only.
This product is available for shipping to the United States, Canada, and Puerto Rico only.

Product Highlights

  • Field Metrology Well, 33 °C to 350 °C, w/9143-INSX, w/Process Electronics
  • Temperature Range at 23 °C: 33 °C to 350 °C (91 °F to 662 °F)
  • Display Accuracy: ± 0.2 °C Full Range
  • Stability: ± 0.02 °C at 33 °C ± 0.02 °C at 200 °C ± 0.03 °C at 350 °C
  • Axial Uniformity at 40 mm (1.6 in): ± 0.04 °C at 33 °C ± 0.1 °C at 200 °C ± 0.2 °C at 350 °C
  • Radial Uniformity: ± 0.01 °C at 33 °C ± 0.015 °C at 200 °C ± 0.02 °C at 350 °C
  • Loading Effect (with a 6.35 mm reference probe and three 6.35 mm probes): ± 0.015 °C Full Range
  • Hysteresis: 0.03°C
  • Operating Conditions: 0 °C to 50 °C, 0 % to 90 % RH (non-condensing)
  • Environmental Conditions (for all specifications except temperature range): 13 °C to 33 °C
  • Immersion (Well) Depth: 150 mm (5.9 in)
  • Insert OD: 25.3mm (1.00 in)
  • Heating Time: 5 min: 33 °C to 350 °C
  • Cooling Time: 32 min: 350 °C to 33 °C 14 min: 350 °C to 100 °C
  • Resolution: 0.01 °
  • Display: LCD, °C or °F user-selectable
  • Size (H x W x D): 290 mm x 185 mm x 295 mm (11.4 x 7.3 x 11.6 in)
  • Weight: 7.3 kg (16 lb)
  • The process version provides a built-in two-channel thermometer readout that measures PRTs, RTDs, thermocouples, and 4-20 mA transmitters which includes the 24 V loop supply to power the transmitter.

Each Unit Includes

  • Insert B
  • RS-232 and 9930 Interface-it control software
  • Test Leads