Order #: NORMA-6003
Mfg #: 5125180
Fluke NORMA 6003 Portable Power Analyzer without Speed & Torque, Three-Channel
Order #: NORMA-6003
Mfg #: 5125180
Product Highlights
The Fluke 6000 Series Portable Wideband Precision Power Analyzers give you more freedom than ever before to make high accuracy power measurements wherever you need to whether in the lab, or in the field. Designed for portability the lightweight, battery powered Fluke 6000 Series eliminates the need to carry large, fragile, expensive analyzers in to environments not suited to them, allowing you to go directly to the load and make measurements in nearly any environment.
The Fluke Norma 6000 Series Portable Wideband Precision Power Analyzers give you more freedom than ever before to make high accuracy power measurements wherever you need to-whether in the lab, or in the field. Designed for portability the lightweight, battery powered Fluke 6000 Series eliminates the need to carry large, fragile, expensive analyzers into the field, allowing you to make measurements directly at the load in nearly any environment. By measuring directly at the load, you can discover how the equipment operates under real-world conditions, with real-world variables, not just at a test bench or in the lab.
The Fluke 6003 includes three measurement channels which each consist of a voltage and current input making it ideal for three-phase power measurements. The Fluke 6004 includes four measurement channels giving it the capability to measure three-phase power and DC power simultaneously to enable real-time inverter efficiency measurements under real-world conditions. The Fluke 6003+ and 6004+ models both add the capability to measure mechanical parameters such as speed and torque (from separate transducers) to discover the electrical to mechanical efficiency of the load under a variety of typical operating modes. With the addition of optional measurement accessories, you can even make measurements up to 1,500V DC and 2,000A AC+DC on conductors with a diameter of up to 52mm.
The instrument's compact, battery-powered design combined with a wideband frequency response makes it easier than ever to make measurements on hard to access systems such as inverter drive systems, DC-AC and AC-DC power conversion systems and electric motors without removing them from service. Making these measurements in the field simplifies the troubleshooting and per-formance measurement processes without sacrificing uptime, giving you more accurate test results that will enable you to discover whether your loads are operating as effectively and efficiently as they should be.
- Continuously operate for up to 6 hours without an external power supply using the 5000mAh Li-ion Internal Battery.
- Measure safely-safety rated for CAT III 1000V, CAT IV 600V environments
- Measure three phase AC and DC power
- Measure three phase power and DC output power at the same time with 3 or 4 channel models, with voltage and current inputs on each channel.
Norma 6003: 3 Voltage + 3 Current | Norma 6003+: 3 Voltage + 3 Current + 1 Motor | Norma 6004: 4 Voltage + 4 Current | Norma 6004+: 4 Voltage + 4 Current + 1 Motor | |
---|---|---|---|---|
Sample rate | 200ks/s | |||
Measurement update rate | 100ms, 200ms, 500ms, 1s | |||
Dimensions (H * W * L) | 298mm x 215m x 96mm | |||
Weight | 3.5 kg (7.7 lbs) | |||
Display | 5.7 inch, TFT LCD, 640x480 | |||
Operating temperature | -10 °C to +50 °C | |||
Storage temperature | -30 °C to +60 °C | |||
Operating humidity | Non-condensing (< 10 °C ) | ≤ 90 % RH (at 10 °C to 30 °C) | ≤ 75 % RH (at 30 °C to 40 °C) | ≤ 45 % RH (at 40 °C to 50 °C) |
Operating altitude | 2000m | |||
Storage altitude | 12000m | |||
Ingress protection | IP 50 (Terminals mated) according to IEC 60529: | |||
Battery | Battery BP 291, 10.8V/5000mAh, 54Wh IEC 62133, UN38.3 | |||
Battery Operating time: 10 Hours (on battery) | ||||
Battery Safety | IEC 61010-1: Pollution Degree 2 | |||
IEC 61010-2-030: CAT IV 600V, CAT III 1000 V | ||||
EMC | IEC 61326-1: Industrial | |||
IEC 61326-2-2 | ||||
Warranty | 1 Year | |||
Communication Interface | USB/RS485 | |||
Dual Analyzer Synchronization Mode | Able to extend to 6, 7 or 8 channels (using multiple instruments) | |||
PC Software | Fluke Power Analyzer software | |||
Storage Capacity | 32GB | |||
Data trend storage rate As per display rate | As per display rate | |||
Main Function Meter, Scope, Harmonic, Phasor, Trend | Meter, Scope, Harmonic, Phasor, Trend | |||
Measuring Parameters | RMS, DC Component, AC Component, Rectified Mean, Peak Value, Peak-Peak, Crest Factor, Form Factor, Fundamental Component, Fundamental Content, Harmonic Distortion, Harmonic Content, Harmonic Factor for voltages and currents, Active Power, Reactive Power, Apparent Power, Power Factor, Phase Shift, Efficiency, Impedance, Electric Energy, Charge/Discharge capacity (Ah), Frequency, Motor Speed, Torque, Mechanical Power, Mechanical Energy, Summation function |
Electrical Specifications | |
---|---|
Voltage | |
Range | 10 V, 100 V, 1000 V |
Crest Factor | CF ≤ 2 |
Maximum Voltage | 10 % overload |
Input Impedance | 2M Ω/10pF (Typical) |
Temperature Coefficient | 0.05 * (Spec)/k |
Bandwidth | 1000V range: 500kHz; 100V range: 200 kHz; |
10V range:100 kHz | |
CMRR | 120 dB @ 50/60 Hz |
Accuracy (% reading + % range) | ||||
---|---|---|---|---|
Range | 1000 V | 100 V | 10 V | |
DC | 0.1 + 0.1 | 0.1 + 0.1 | 0.1 + 0.2 | |
AC (10Hz to 1kHz) | 0.1 + 0.1 | 0.1 + 0.1 | 0.1 + 0.2 | |
AC (10kHz) | 5 + 0.5 | 5 + 0.5 | 5 + 0.5 | |
Current | ||||
Crest Factor | CF ≤ 2 | |||
Temperature Coefficient | 0.05 x (Spec)/k | |||
Overload capacity | 10 % overload | |||
CMRR | 120 dB @ 50/60 Hz | |||
Shunt (current input) | ||||
Measuring Range | 0.1 A, 1 A, 10 A | |||
Input Impedance | 0.025 Ω (Typical) | |||
Bandwidth | 10 A range: 500 kHz; 1 A range: 200 kHz; 0.1 A range: 100 kHz | |||
BNC (voltage input) | ||||
Range | 0.1 V, 1 V, 10 V | |||
Input Impedance | 100k Ω/100pF (Typical) | |||
Bandwidth | 10 V range: 500 kHz; 1 V range: 200 kHz; 0.1 V range: 100 kHz |
Accuracy (% reading + % range) | |||||||
---|---|---|---|---|---|---|---|
Range | 10 A | 1 A | 0.1 A | 10 V | 1 V | 0.1 V | |
DC | 0.1 + 0.2 | 0.1 + 0.5 | 0.1+2 | 0.1+0.1 | 0.1+0.2 | 0.1+1 | |
AC (10Hz to 1kHz) | 0.1+0.1 | 0.1+0.2 | 0.1+1 | 0.1+0.1 | 0.1+0.1 | 0.1+0.5 | |
AC (10kHz) | 5+1 | 5+1 | 5+1 | 5+1 | 5+1 | 5+1 | |
Motor Module (Torque and Speed) | |||||||
Voltage Range | ±10 V dc, 10 % overload | ||||||
Voltage Channels | 2 | ||||||
Input Impedance | 1.1M Ω (Typical) | ||||||
Accuracy at dc | 0.1 % range + 0.1 % reading | ||||||
Pulse Channels | 3 | ||||||
Pulse Logic High Threshold | 2 V (Typical) | ||||||
Pulse Logic Low Threshold | 0.8 V (Typical) | ||||||
Maximum Pulse Frequency | 100 kHz | ||||||
Frequency Domain Measurement | |||||||
Frequency Accuracy | 0.05 % range + 0.05 % reading | ||||||
Harmonics | 100 (50Hz/60Hz) | ||||||
Calculation method | FFT/Interpolation |