Order #: CP031A-RENT2
Mfg #: CP031A-RENT2
Lecroy CP031A for Rent, High Sensitivity Current Probe, 30A/100MHz
Order #: CP031A-RENT2
Mfg #: CP031A-RENT2
Product Highlights
Wide Range of Applications
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
High Sensitivity
The CP030A and CP031A provide a high sensitivity of 1mA/div. This allows for more precise low current measurements on Teledyne LeCroy oscilloscopes. When used with HDO high definition oscilloscopes with HD4096 technology, users will obtain highly accurate, low current waveforms with unmatched 12-bit resolution for improved debug and analysis.
Fully Integrated
All Teledyne LeCroy current probes are powered through the Teledyne LeCroy ProBus connection and require no additional hardware. Along with providing power, the ProBus connection allows the current probe and oscilloscope to communicate, resulting in current waveforms automatically displayed on screen in Amps, and calculated power traces scaled correctly in Watts. This full integration also allows for the Degauss and Autozero functions to be done directly from the oscilloscope's user interface.
Deskew Calibration Source
The DSC015 deskew calibration source has both voltage and current time-aligned signals, which enables the precise deskew of voltage and current probes. Most voltage probes along with the CP030, CP030A, CP031, and CP031A are compatible with the DSC015.
Electrical Characteristics | |
Bandwidth (Probe Only) | 100 MHz |
Coupling | AC 1 MΩ, DC 1MΩ, GND |
Risetime (typical) | 3.5 ns |
Max Continuous Input Current | 30 A |
Max Peak Current (non-continous) |
50 A |
Minimum Sensitivity | 1 mA/div |
Amplitude Accuracy | ±1% of reading to 30 A ±2% of reading to 50 A |
Maximum Circuit Voltage | 300 V, CAT I (Insulated Wire) |
Environmental and Safety | |
Operating Temperature | 0 °C to 40 °C |
Humidity | ≤ 80 % relative humidity (non-condensing) |
Storage Temperature | -10 °C to 50 °C |
Max Altitude | 2000 m |
Physical Dimensions | |
Probe Head Dimensions (L x W x H) | 175 mm x 18 mm x 40 mm |
Cable Length | 1.5 m |
Maximum Conductor Size | 5 mm |
Weight | 260 g |
Interface | ProBus |