Best accuracy, reproducibility and long-term stability
Highest safety due to gastight feedthrough with capabilities up to SIL2/3, certified to IEC 61508
Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
Cost savings with modular concept for easy replacement of sensor, display or electronics
Overload-resistant up to 420bar / 42MPa / 6300psi, function-monitored
Seamless and independent system integration (HART/PA/FF)
Field of Application
For level, volume or mass measurement in liquids, differential pressure monitoring as well as flow measurement (volume or mass flow) in conjunction with primary elements in gases, vapors and liquids.
Process connections: Threads
Process temperature: -40 to +120°C (-40 to +248°F)
Measuring ranges: 0.25mbar to 40bar (0.0036 to 600psi)
Digital transmitter with metallic measuring diaphragms Modular transmitter Long term stability High static pressure/Overload resistance Enhanced safety via self diagnostic functions Secondary process barrier
Supply / Communication
4...20 mA HART: 10,5...45V DC Ex ia: 10,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC
Accuracy
Standard: 0.05%
Platinum: up to 0.035%
Long term stability
0,05% of URL/year
Ambient temperature
-40°C...85°C (-40°F...185°F)
Process temperature
-40°C...120°C (-40°F...248°F)
Process pressure absolute / max. overpressure limit
HistoROM/M-Dat 4-line digital display SS- or Aluminiumhousing Separate housing
Application limits
Measuring cell:
Metal welded
Gas/Liquids
Measuring Principle
Differential pressure
Product headline
Digital transmitter with metallic measuring diaphragms Modular transmitter Long-term stability High static pressure/Overload resistance Enhanced safety via self diagnostic functions Secondary process barrier
ATEX FM CSA NEPSI IECEx SIL NACE Schiffbau GL WHG/ Überfüllsicherung EN 10204-3.1
<>Differential pressure<>Characteristic<>4...20mA HART
10,5...45V DC (Non Ex):
Ex ia: 10,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex)
Pressure
Measuring Principle
Digital transmitter with metallic measuring diaphragms Modular transmitter Long-term stability High static pressure/Overload resistance Secondary process barrier
HistoROM/M-Dat 4-line digital display SS- or Aluminium housing Separate housing
Specialities
Diagnostic functions
Steam
Measuring Principle
Differential pressure
Product headline
Digital transmitter with metallic measuring diaphragms Modular transmitter Long-term stability High static pressure/Overload resistance Enhanced safety via self diagnostic functions Secondary process barrier
Max. measured error
0,075% "PLATINUM" 0,05%
Max. process pressure
max. 420bar (max. 6.091 psi)
Medium temperature range
Temperature gradient from pressure piping
Display/Operation
Option
Outputs
4...20mA HART PROFIBUS PA FOUNDATION Fieldbus
Digital communication
HART PROFIBUS PA FOUNDATION Fieldbus
Hazardous area approvals
ATEX FM CSA NEPSI IECEx SIL NACE Schiffbau GL WHG/ Überfüllsicherung EN 10204-3.1