The Endress+Hauser iTEMP TMT162 Temperature Field Transmitter
Endress+Hauser iTEMP TMT162 Temperature Field Transmitter

Order #: Endress+Hauser iTEMP TMT162 Temperature Field Transmitter

Questions about availability or need help? Contact Us:

(800) 633-0561

The Endress+Hauser iTEMP TMT162 Temperature Field Transmitter

Endress+Hauser iTEMP TMT162 Temperature Field Transmitter

Order #: Endress+Hauser iTEMP TMT162 Temperature Field Transmitter

Unsurpassed reliability, accuracy and long-term stability in critical processes. The remote configurable transmitter transfers and monitors converted signals from RTD sensors and thermocouples as well as from resistance and voltage signals using selectively HART®, FOUNDATION Fieldbus™-, PROFIBUS® PA-communication. It visualizes the signals on its own backlit display. A field housing allows a direct connection in harsh process areas as well as in hygienic applications as option.

Availability: Ships in 2-3 Weeks
Grouped product items
Product Name Qty
No options of this product are available.

Product Highlights

  • High reliability in harsh industrial environments due to dual compartment housing and compact, fully potted electronics
  • Backlit display with large measured value, bargraph and status condition indication
  • Diagnostics information according to NAMUR NE 107
  • Reliable operation due to sensor monitoring: breakdown information, sensor backup, drift alarm and corrosion detection
  • High measuring point accuracy due to sensor transmitter matching
  • Mathematical functions for differential and average temperature add flexibility to the measurement
  • Optional: stainless steel housing for hygienic or Ex d application

Field of Application

  • Universal input usable for resistance thermometer (RTD), thermocouple (TC), resistance thermometer (Ω), voltage transmitters (mV)
  • HART® protocol for converting various input signals to a scalable 4 to 20 mA analog output signal. Operating the transmitter using handheld terminals Field Xpert SFX100, DXR275/375/475 or remotely via PC
  • FOUNDATION Fieldbus™ ITK 6.1.2
  • PROFIBUS® PA Profile 3.02
  • Optional: stainless steel housing for hygienic or Ex d application
Win a Generac Generator when purchasing $750 or more from Transcat.Win a Generac Generator when purchasing $750 or more from Transcat.
Temperature Transmitters
Measuring PrincipleResistance Temperature Detector
Input2 x RTD, TC, Ohm, mV
Output4...20 mA HART
FOUNDATION Fieldbus H1
PROFIBUS PA
Auxiliary power supplyHART:
10,5...40 V DC
Ex ia: 10,5...30 V DC
FOUNDATION Fieldbus:
9...32 V DC
Ex ia: 10,5...24 V DC
PROFIBUS PA:
9...32 V DC Ex ia: 10,5...24 V DC
CommunicationHART-protocol
FOUNDATION Fieldbus
PROFIBUS PA
Installationin field
Accuracy(Pt100, -50...200 °C) <= 0,15 K (HART)
(Pt100, -58...392 °F) <= 0,3 °F (HART)
(Pt100) <= 0,1 K (FF, PA)
(Pt100) <= 0,18 °F (FF, PA)

Galvanic isolationyes
CertificationUL rec. Comp (HART)
FM IS, NI I/1+2/ABCD
CSA IS, NI I/1+2/ABCD
ATEX II1G Ex ia IIC T6
ATEX II2G Ex d IIC T6
ATEX II3G Ex nA IIC T6
ATEX II3G Ex ic IIC T6
ATEX IECEx II2D Ex tb IIIC Db
ATEX II1G Ex ia IIC T6, II2D Ex ia IIIC
FM XP, NI, DIP I,II,III/1+2/A-G
CSA XP, NI, DIP I,II,III/1+2/A-G
FM XP, DIP, IS, NI I,II,III/1+2/A-G
CSA XP, DIP, IS, NI I,II,III/1+2/A-G
FM+CSA XP,DIP, IS, NI I,II,III/1+2/A-G
CSA General Purpose
IECEx Ex ia IIC T6 Ga
IECEx Ex d IIC T6 Gb
IECEx Ex ia, Ex d
NEPSI Ex ia IIC T4-T6
NEPSI Ex nA II T4-T6
NEPSI Ex d IIC T4-T6
TIIS Ex ia IIC T4
TIIS Ex ia IIC T6
TIIS Ex d IIC T6

marine approval only for HART-protocol
SIL2 only for HART-protocol
Thermometer
Measuring PrincipleResistance Temperature Detector
CertificationUL rec. Comp (HART)
CSA GP
ATEX
FM
CSA
TIIS
NEPSI
IECEx