Order #: CM85-2
Mfg #: CM85-2
FLIR CM85-2 1000A, True RMS Power Clamp Meter with Wireless METERLiNK
Order #: CM85-2
Mfg #: CM85-2
Product Highlights
The FLIR CM85-2 is an industrial power clamp meter with advanced power analysis and variable frequency drive (VFD) filtering functions required by electrical troubleshooters for full-scale equipment. Accurately analyze voltage in complex machinery by including harmonics, inrush, current, and phase rotation testing with a wide AC/DC voltage range and base accuracy of +/-1%. Stream live data in real time from the CM85-2 to your mobile device over Bluetooth®. Using the METERLiNK® app, you can compare log files, create alarm thresholds, visualize trends, and create reports to share with team members.
Superior Power Analysis
VFD mode increases accuracy when working on VFD-controlled equipment. Conduct multiple conductor measurements with True RMS AC Current up to 1000 Amps.
Purpose Built for Inspections
Dual LED lights eliminate the need to carry additional tools, and an ergonomic industrial design offers ease of use and operation.
Inspect at a Safe Distance
Stream live readings in real time from the meter to your mobile device over Bluetooth using the METERLiNK app from a distance up to 10 m (32 ft).
Jaw Opening | 45 mm (1.77 in) |
AC Current | 99.99 A, 50-60 Hz ± (2% + 5 digits); >60-400 Hz ± (2.5% + 5 digits) 999.9 A, 50-60 Hz ± (2% + 5 digits); >60-400 Hz ± (2.5% + 5 digits) |
Safety Category | CAT IV-600 V, CAT III-1000 V |
Measurement & Analysis | |
---|---|
AC Current | 99.99 A, 50-60 Hz ± (2% + 5 digits); >60-400 Hz ± (2.5% + 5 digits) 999.9 A, 50-60 Hz ± (2% + 5 digits); >60-400 Hz ± (2.5% + 5 digits) |
AC Voltage | 99.99 V, 50-500 Hz ±(1.0% + 5 digits) 999.9 V, 50-500 Hz ±(1.0% + 5 digits) |
Capacitance | 3.999 µF, ±(1.9% + 8 digits) 39.99 µF, ±(1.9% + 8 digits) 399.9 µF, ±(1.9% + 8 digits) 3.999 mF, ±(1.9% + 8 digits) |
Continuity | 999.9 Ω, ±(1.0% + 5 digits) |
DC Current | 99.99 A, ±(2% + 0.5 A) 999.9 A, ±(2% + 5 digits) |
DC Voltage | 99.99 V, ±(0.7% + 2 digits) 999.9 V, ±(0.7% + 2 digits) |
Diode | 0.40 to 0.80 V, ±0.1 V |
Frequency | 20.00 to 99.99 Hz, ±(0.5% + 3 digits) 20.0 to 999.9 Hz, ±(0.5% + 3 digits) 0.020 to 9.999 kHz, ±(0.5% + 3 digits) |
Harmonics | Total harmonic distortion ACA/ACV: 99.9%, ±(3.0% + 10 digits) Harmonic distortion: H01-H12 99.9%, ±(5% + 10 digits) Harmonic distortion: H13-H25 99.9%, ±(10% + 10 digits) |
Inrush Current | ACA: 99.99 A, ±(3% + 0.3 A) 999.9 A, ±(3% + 5 digits) |
Measuring Rate | 3 times per second |
Peak Hold | ACV: 140.0 V, ±(3.0% + 15 digits) 1400 V, ±(3.0% + 15 digits) ACA: 140.0 A, ±(3.5% + 15 digits) 1400 A, ±(3.5% + 15 digits) |
Power Factor | -1.00 to 0.00 to +1.00, ±3° ±1 digit |
Recording | Data recording available via METERLiNK App |
Resistance | 999.9 Ω, ±(1.0% + 5 digits) 9.999 kΩ, ±(1.0% + 3 digits) 99.99 kΩ, ±(1.0% + 3 digits) |
VFD | ACV: 99.99 V, 50-60 Hz ±(1% + 5 digits) 999.9 V, 50-60 Hz ±(1% + 5 digits) ACA: 99.99 A, 50-60 Hz ±(2% + 5 digits) 999.9 A, 50-60 Hz ±(2% + 5 digits) |
Watts | DC: 9.999 kW (10 V, 5 A min), ±(3% + 0.05 kW) 99.99 kW (10 V, 5 A min), ±(3% + 0.5 kW) 999.9 kW (10 V, 5 A min), ±(3% + 10 digits) AC: 9.999 kW (10 V, 5 A min), ±(3% + 10 digits) 99.99 kW (10 V, 5 A min), ±(3% + 10 digits) 999.9 kW (10 V, 5 A min), ±(3% + 10 digits) |
Communication & Data Storage | |
Bluetooth range max | 10 m (32 ft) |
Power | |
Auto Power Off | Approximately 30 minutes |
Battery Life | 50 hours with alkaline batteries (backlight, work light, and Bluetooth are off) |
Power Requirements | 6 x 1.5 V AAA alkaline batteries |
General | |
Dimensions (L x W x H) | 276 mm x 101 mm x 50 mm (10.87 in x 3.98 in x 1.97 in) |
Jaw Opening | 45 mm (1.77 in) |
Weight | Total weight including batteries: 0.65 kg (1.43 lb) |
Worklights | Yes |
Environmental & Certifications | |
Certifications | UL, CE, FCC, IC, UKCA, CSAUS |
Drop test | 1.2 m (4 ft) |
EMC | FCC: 47 CFR Part 15 Subpart B CE: EN IEC 61326-1:2021 EN IEC 61326-2-2:2021 EN 301 489-1 V2.2.3 (2019-11) EN 301 489-17 V3.2.4 (2020-09) RF: ETSI EN 300 328 V2.2.2 EN 62479:2010 EN 50663:2017 |
Operating Temp & Humidity | 0°C to 10°C (32°F to 50°F) (non?condensing) 10°C to 30°C (50°F to 86°F) (≤80% RH) 30°C to 40°C (86°F to 104°F) (≤75% RH) 40 to 50°C (104°F to 122°F) (≤45% RH) |
Safety Category | CAT IV-600 V, CAT III-1000 V |
Safety Standards | IEC 61010-1:2010, IEC 61010-2-032:2012, IEC 61010-2-033:2012 |
Shock & Vibration | Random vibration per MIL?PRF?28800F Class 2 (5 Hz to 55 Hz, 3 g maximum) |
Storage temperature and relative humidity [RH] | -10°C to 50°C (14°F to 122°F). 0-80% RH (batteries not fitted) |
Temperature Coefficient | 0.2 x (specified accuracy)/°C, <18°C, >28°C |