Fluke 568-EX/ETL for Rent, Intrinsically Safe Mini Infrared Thermometer
Intrinsically Safe Mini Infrared Thermometer

Order #: 568-EX-RENT1

Mfg #: 568-EX-RENT1

Questions about availability or need help? Contact Us:

(800) 633-0561
Call for price
Call for price

Fluke 568-EX/ETL for Rent, Intrinsically Safe Mini Infrared Thermometer

Intrinsically Safe Mini Infrared Thermometer

Order #: 568-EX-RENT1

Mfg #: 568-EX-RENT1

Call for price

Request a Rental Quote

Have a Question? Speak to a Transcat Rental Expert: 800.264.4059

Call for price
Availability:
In stock
This product is available for shipping to the United States, Canada, and Puerto Rico only.

Product Highlights

The Fluke 568 Ex Intrinsically Safe Infrared Thermometer is the one product you can use in Class I Div 1 and Div 2 or Zone 1 and 2 hazardous environments anywhere in the world. Whether you work in petroleum, chemical, oil and gas, or pharmaceutical environments, the 568 Ex allows you to carry the most trusted name in test tools into most Ex rated areas all around the globe.

With a straight-forward user interface and soft-key menus, the Fluke 568 Ex makes even complex measurements easy. Quickly navigate and adjust emissivity, save data or turn on and off alarms, with just a few pushes of a button. All in a single intrinsically safe tool certified by major rating bodies from around the world.

  • Intrinsically safe temperature measurements. Anywhere in the world
  • Measure -40 °C to 800 °C
  • (-40 °F to 1472 °F) with ± 1 %
  • Measurement Accuracy
  • Conductive Case for Carrying into
  • Hazardous Areas
  • 50:1 Distance-to-Spot Ratio
  • Compatible with Standard K-Type
  • Mini-Connector Thermocouple
  • (KTC) Probe
  • Adjustable Emissivity, Built-in
  • Material Table
  • Capture up to 99 Points of Data
  • Two-Year Warranty
Transcat Rentals - Rent Equipment from the Industry Leader
   Try Before You Buy
   Save Time & Money
   Weekly and Monthly Rentals
   Access Our Large Inventory
   Long-term Discounts and Rent-to-Buy Options Available

Shop all Rentals

Win a Generac Generator when purchasing $750 or more from Transcat.Win a Generac Generator when purchasing $750 or more from Transcat.
Specifications
Infrared temperature range -40°C to 800°C (-40°F to 1472°F)
Infrared accuracy < 0°C (32°F): ±(1.0°C (±2.0°F) + 0.1°/1°C or°F);
> 0°C (32°F): ±1% or ±1.0°C (±2.0°F), whichever is greater
Display resolution 0.1°C / 0.1°F
Infrared spectral response 8 µm to 14 µm
Infrared response time < 500 ms
Thermocouple type-k input temperature range -270°C to 1372°C (-454°F to 2501°F)
Thermocouple type-k input accuracy < -40°C: ±(1°C + 0.2°/1°C)
≥ -40°C: ±1% or 1°C, whichever is greater < -40°F: ±(2°F + 0.2°/1°F)
≥ -40°F: ±1% or 2°F, whichever is greater
D:S (distance to measurement spot size) 50:01:00
Laser sighting Single-point laser
Minimum spot size 19 mm (0.75 in)
Emissivity adjustment By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01
Data storage 99 points
Hi/Low alarms Audible and two-color visual
Min/Max/Avg/Dif Yes
Display Dot matrix with function menus
Backlight Two levels, normal and extra bright for darker environments
Trigger lock Yes
Switchable celsius and fahrenheit Yes
Power 2 AAA/LR03 type-approved batteries (For a list of type-approved batteries, refer to Product Safety Instructions.)
Battery life 4 hours with laser and backlight on; 
100 hours with laser and backlight off, at 100% duty cycle
Operating temperature 0°C to 50°C (32°F to 122°F)
Storage temperature -20°C to 60°C (-40°F to 140°F)
Bead thermocouple type-k range -40°C to 260°C (-40°F to 500°F)
Bead thermocouple type-k accuracy ±1.1°C (2.0°F) from 0°C to 260°C (32 °F to 500°F), 
typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F)



Visit our Fluke Thermometer Selection Guide

How to Rent from Transcat

Rent from Transcat - Step 1

1. Select Your Rental Product

  • Need help selecting a unit? Try using our Product Finder or search our available units
  • Can’t find what you are looking for? Is the rental unit you need, not available? Give us a call at 800-828-1470 or our chat feature to speak with one of our dedicated Rental Experts
Rent from Transcat - Step 2

2. Contact Our Team of Rental Experts

  • Contact us here or click below to submit your request for a rental quote and a member of our Rental Team will review the request and will reach out to you very soon
Rent from Transcat - Step 3

3. Select Your Rental Period & Complete Your Order

  • Our weekly period lasts 7 calendar days, while our monthly rental period lasts 28 calendar days
  • Provide your form of payment, sign the rental agreement and any other required documents, and we will ship you the unit