Used Fluke Calibration 1524H 2-Channel Reference Handheld Thermometer
2-Channel Reference Handheld Thermometer

Order #: 1524H-USED

Mfg #: 1524H

Questions about availability or need help? Contact Us:

(800) 633-0561
$2,299.00

Used Fluke Calibration 1524H 2-Channel Reference Handheld Thermometer

2-Channel Reference Handheld Thermometer

Order #: 1524H-USED

Mfg #: 1524H

$2,299.00

Request a Used Instrument Quote

Have a Question? Speak to a Transcat Expert: 800.264.4059

Used instruments from TranscatTranscat Used Instrument Guarantee
Calibration Certificate Included 6 Month Warranty Unsurpassed Service & Support

Availability: Call for Availability
This product is available for shipping to the United States, Canada, and Puerto Rico only.
This product is available for shipping to the United States, Canada, and Puerto Rico only.
This product is available for shipping to the United States, Canada, and Puerto Rico only.
This item is available as RENTAL at
Call for price
Shop now
This item has NEW version starting at
$3,175.00
Shop now

Product Highlights

  • Requires optional probe, sold separately
  • Measurement Capability Channel 1: 4-wire RTD, Thermistor, Thermocouple, Resistance, Voltage
  • Measurement Capability Channel 2: 4-wire RTD, Thermistor, Resistance
  • Accuracy to ±0.002 °C with thermistors and ± 0.015°C with PRTs
  • Temperature range: -200°C to 2315°C
  • Simultaneously measures two channels
  • Reads PRTs, thermocouples, and thermistors
  • "Plug-and-play" calibration coefficients with SMART LEMO connector
  • Trends data graphically
  • Documents readings and statistics
  • Logs up to 15,000 data points
  • Graphing Yes
  • Documenting 25 readings
  • Auto Logging 15,000 readings
  • Statistics Average, Stdev, Max, Min
  • Internal real-time clock
  • Units °C, °F, Ω, mV
  • Environmental conditions for all
  • specifications 13°C to 33°C and 0 to 90% RH
  • Storage Temperature -20°C to 70°C
  • RTD Resistance Accuracy 0.004% + 0.002 Ω percent of reading + floor
  • Thermistor Resistance Accuracy 0.01% + 0.5 Ω percent of reading + floor
  • Thermocouple Voltage Accuracy 0.005% of reading + 5µV floor
  • TC Reference Junction Compensation Accuracy 0.35°C
  • TC Measurement Capability Types J, K, T, E, R, S, B, L, U, C, M and N
  • Weight (kg) 0.65
  • Dimensions WxHxL (mm) 96x200x47
  • Computer Communications RS-232 - SCPI protocol
  • Baud Rate 2400, 9600
  • Power Requirements 3 AA Batteries
  • DC universal power supply
  • Minimum Battery Life 20 hours