Fluke Calibration 5609-9BND-P Secondary PRT Probe, 100ohm, 9" 90 Degree Bend for the 1523/1524
Secondary PRT Probe, 100ohm, 9" 90 Degree Bend for 1523/1524
Order #: 5609-9BNDP
Mfg #: 3376832
$2,024.00
Fluke Calibration 5609-9BND-P Secondary PRT Probe, 100ohm, 9" 90 Degree Bend for the 1523/1524
Secondary PRT Probe, 100ohm, 9" 90 Degree Bend for 1523/1524
Order #: 5609-9BNDP
Mfg #: 3376832
$2,024.00
Availability: Ships in 3-4 weeks
Product Highlights
- If you want a very stable thermometer from -200 °C to 670 °C and are particular about the calibration, then look no further than our 5609 Secondary Reference PRT
- Its short-term stability at the triple point of water is only ± 10 mK and its one-quarter inch (6.23 mm) diameter lets you get accurate measurements in only 100 mm of immersion
- With multiple sheath length options on both of these probes, and an optonal 90 ° bend at nine inches from the tip for dry-well applications, you can find the dimensions that are just right for your specific application
- The 5609 comes with a one-quarter inch (6.35 mm) diameter sheath in lengths of 12 inches, 15 inches, and 20 inches; or with a 6 mm diameter in lengths of 300 mm, 400 mm, or 500 mm
- When looking for improved response time and reduced stem effect in shallow immersion, look for small diameter probes, because the measurement error called stem effect is caused by the diameter of the stem rather than the length of the stem
- Both of these probes have Inconel™ sheaths and are made using a special manufacturing process, giving them great precision over a wide temperature range
- The sensors for these probes are reference-grade platinum and feature four-wire connections with less noisy measurements than two-wire counterparts
Webinars
Automating and Documenting Temperature Calibration Webinar with Fluke Calibration
Differential Pressure Meter Gas Custody Transfer Calibration Webinar with Fluke
All products in this series
-
Fluke Calibration 5609-300-P Secondary PRT Probe, 100ohm, 6x300mm for the 1523/1524Secondary PRT Probe, 100ohm, 6x300mm for 1523/1524$1,659.00
-
Fluke Calibration 5609-20-S Secondary Reference PRT Probe -200 to 670C, Spade Lugs, 1/4x20"Secondary Reference PRT Probe -200 to 670C,Spade Lugs,1/4x20"$2,076.00
-
Fluke Calibration 5609-20-B Secondary PRT Probe, 100ohm, 1/4x20", Bare WireSecondary PRT Probe, 100ohm, 1/4x20", Bare Wire$2,076.00
-
Fluke Calibration 5609-20-P Secondary PRT Probe, 100ohm, -200 to 670C, 1/4x20" for the 1523/1524Secondary PRT Probe, 100ohm, -200 to 670C, 1/4x20" 1523/1524$2,076.00
-
Fluke Calibration 5609-20-D Sccondary PRT Probe, 100ohm, 1/4x20", 5-Pin DINSccondary PRT Probe, 100ohm, 1/4x20", 5-Pin DIN$2,076.00
-
Fluke Calibration 5609-500-B Secondary Reference PRT Probe -200 - 670C, Bare Wire, 6x500mm11condary Reference PRT Probe -200 - 670C, Bare Wire, 6x500mm$2,076.00
-
Fluke Calibration 5609-20-J Secondary PRT Probe, 100 Ohm 1/4x20", Bare WireSecondary PRT Probe,100ohm 1/4x20",Bare Wire$2,076.00
-
Fluke Calibration 5609-9BND-L Secondary PRT Probe, 100ohm, 9" 90 Degree Bend mini spade lugsSecondary PRT Probe, 100ohm, 9" 90 Degree Bend mini spade lugs$2,024.00
-
Fluke Calibration 5609-9BND-A Secondary PRT Probe, 100ohm, 9" 90 Degree Bend for the 914XSecondary PRT Probe, 100ohm, 9" 90 Degree Bend for 914X$2,024.00