Fluke Calibration 5626-12-A Secondary PRT Probe, 100 ohm 1/4" Diameter x 12"
Secondary PRT Probe, 100 ohm 1/4" Diameter x 12"
Order #: 5626-12-A
Mfg #: 3055440
$3,807.00
Fluke Calibration 5626-12-A Secondary PRT Probe, 100 ohm 1/4" Diameter x 12"
Secondary PRT Probe, 100 ohm 1/4" Diameter x 12"
Order #: 5626-12-A
Mfg #: 3055440
$3,807.00
Availability: Ships in 3-4 weeks
Product Highlights
- Secondary Standard PRT Temperature Sensors
- High-temp PRT, 100 Ω
- Temperature Range: –200 °C to 661 °C
- Handle Temp: 0 °C to 80 °C
- RTPW: 100Ω (±1Ω)
- W(Ga): ³ 1.11807
- Calibration Uncertainty (k=2): ±0.006 °C at –200 °C ±0.004 °C at 0 °C ±0.009 °C at 420 °C ±0.014 °C at 661 °C
- Stability: ±0.003 °C
- Long-Term Drift: < 0.03 °C/500 hours at 661 °C
- Immersion: At least 12.7 cm (5 in) recommended
- Sheath: Inconel™ 600
- Lead Wires: 4-wire Super-Flex PVC, 22 AGW
- Termination: Bare Wire
- Size: 0.25" dia. x 12"
Each Unit Includes
- Accredited Calibration
Webinars
Automating and Documenting Temperature Calibration Webinar with Fluke Calibration
Differential Pressure Meter Gas Custody Transfer Calibration Webinar with Fluke
All products in this series
-
Fluke Calibration 5626-15-D Secondary PRT Probe, 100 ohm 1/4" Diameter x 15"Secondary PRT Probe, 100 ohm 1/4" Diameter x 15"$3,923.00
-
Fluke Calibration 5626-12-G Secondary PRT Probe, 100 ohm 1/4" Diameter x 12"Secondary PRT Probe, 100 ohm 1/4" Diameter x 12"$3,826.00
-
Fluke Calibration 5626-12-S Secondary Std PRT Temp Sensor, 100ohm, -200C- 661C, Spade LugsSecondary Std PRT Temp Sensor, 100ohm, -200C- 661C, Spade Lugs$3,826.00
-
Fluke Calibration 5626-15-B Secondary PRT Probe, 100 ohm 1/4" Diameter x 15"Secondary PRT Probe, 100 ohm 1/4" Diameter x 15"$3,923.00
-
Fluke Calibration 5626-12-D Secondary PRT Probe, 100 ohm 1/4" Diameter x 12"Secondary PRT Probe, 100 ohm 1/4" Diameter x 12"$3,826.00
-
Fluke Calibration 5626-12-P Secondary PRT Probe, 100 ohm 1/4" Diameter x 12"Secondary PRT Probe, 100 ohm 1/4" Diameter x 12"$3,807.00
-
Fluke Calibration 5626-12-B Secondary PRT Probe, 100 ohm 1/4" Diameter x 12"Secondary PRT Probe, 100 ohm 1/4" Diameter x 12"$3,826.00
-
Fluke Calibration 5626-15-A Secondary PRT Probe, 100 ohm 1/4" Diameter x 15"Secondary PRT Probe, 100 ohm 1/4" Diameter x 15"$3,910.00
-
Fluke Calibration 5626-15-P Secondary PRT Probe, 100 ohm 1/4" Diameter x 15"Secondary PRT Probe, 100 ohm 1/4" Diameter x 15"$3,904.00
-