The LT5GEO cellular data logger is for the monitoring of location, humidity, shock, light, and temperature during shipping so you can act immediately.
Multi-Use
Instant Alerts: Get immediate notifications of parameter deviations so you can act immediately to protect your shipment
GPS Location: Gain visibility of the location of your shipment with GPS tracking that is uploaded to LogTag Online
Auto Flight Mode: No need to rely on logistics staff to turn on Flight Mode with Auto Flight Mode
Condition Visibility: Know the location and condition of your shipment while it is in transit with location, humidity, shock, light, and temperature sensors
Cloud Connectivity: Data is automatically uploaded to LogTag Online so you can see the data remotely
Compliance: Meets FCC, CE, DO-160H, and FDA 21 CFR Part 11 standards
LogTag Mobile App: Access LT5GEO data on-the-go via LogTag Mobile App
Connectivity: LTE Cat M1/EGPRS
Sensor Measurement Range: -30C to +70C (-22F to 158F)
Operating Temperature Range: -30C to +70C (-22F to 158F)
Storage Temperature Range: 0C to +40C (+32F to +104F)
Humidity Measurement Range: 0 %RH to 100 %RH (non-condensing), with limitations
Humidity Operating Range: 0 %RH to 100 %RH (non-condensing), with limitations
Storage Humidity Range: 5 to 95 %RH non-condensing
Rated Temperature Reading Accuracy:
Better than +/-0.45C (+/-0.8F) for +0C to +50C (+32F to +122F), typically +/-0.3C (0.6F)
Better than +/-0.8C (+/-1.4F) for +50C to +70C (+122F to +158F), typically +/-0.5C (0.9F)
Better than +/-0.95C (+/-1.7F) for -40C to +0C (-40F to +32F), typically +/-0.6C (1.1F)
Actual performance is typically much better than the rated values. Accuracy figures can be improved by recalibration
Rated Humidity Reading Accuracy:
Better than +/-3 %RH for 20 %RH to 80 %RH, typically +/-2 %RH
Better than +/-5 %RH for 0 %RH to 20 %RH, typically +/-4 %RH
Better than +/-5 %RH for 80 %RH to 100 %RH, typically +/-4 %RH
Actual performance is typically much better than the rated values. Accuracy figures can be improved by recalibration
Light Sensor Range: 0-120,000 lux (0-100%)
Shock Sensor Measuring Range: 0-16g
Shock Sensor Resolution: 0.1g
Shock Sensor Sampling Rate: 25Hz
Rate Recording Capacity: 16,320 total log memory
Transmission Interval: 1-24 hours, depending on trip duration set through LogTag Online Uploads immediately when alarm is triggered, regardless of transmission interval.
Sampling Interval: 10 minutes
Logging Start Options: Push button start, with configurable delay, from 1 minute to 72 hours
Environmental: IP61
Software: LogTag Online and (optional) LogTag Mobile App
Power Source: NiMH rechargeable battery
Battery Life: Transmission interval adjusts according to trip duration set in LogTag Online. Maximum Trip length 90 days
Connection Interface: USB 2.0 / USB Type C Metal plug