Fluke FEV100/TY1 & TSL is the first Fluke product for the electric vehicle charging segment. This product comes with Type 1 and Tesla type connectors. It is designed to test function and safety of electric vehicles charging stations, recommended to comply with SAE-J1772 standards for US stations. Provides critical protective ground testing of the station, GFCI troubleshooting and CP communication stages between vehicle and station.
The Fluke FEV100/TY1 & TSL is an adaptor with Type 1 and Tesla type connector that simulates the presence of an electrical vehicle to test the functionality and safety of an electric vehicle AC charging station.
Check that an electric vehicle charging station is correctly wired and that protective earth is functioning properly with the PE pre-test feature.
Perform GFCI troubleshooting of an electric vehicle charging station and verify it is functioning properly for safety.
Test different charging states of an electric vehicle charging station with the turn of a button. Verify the charging voltage using a digital multimeter.
Key Attributes
CP State Simulation: A: ± 12V 1kHz; B: 2.74kϛ +9 V / -12V 1kHz; C: 882ϛ +6 V / -12V 1kHz; D: 246ϛ +3V / -12V 1kHz
Output voltage : Max. 250 V / 60 Hz, CAT II 300 V
Compatibility with other test and measurement tools : Digital multimeter, oscilloscope
Safety Testing : Protective grounding test (PE), GFCI test
SAE J1772 socket (type 1, 5P single-phase) Connector for Tesla™ station
Internal power consumption
2 W max.
Operating temperature
-4 °F to 104 °F (-20 °C to 40 °C)
Storage temperature
-4 °F to 122 °F (-20 °C to 50 °C)
Operating humidity range
10 % to 85 % relative humidity non-condensing
Storage relative humidity
0 % to 85 % non-condensing
Operating altitude
6561 ft (2000 m) max.
Dimensions (H x W x D)
Approx. 8.66 x 4.33 x 1.77 in (220 x 110 x 45 mm) without cable assembly
Weight
Approx. 4.4 lb (2 kg)
Safety standards
IEC 61010-1, Pollution Degree 2
IEC 61010-2-030
Measurement category
CAT II 250 V
IP protection class
IP54
Electromagnetic Compatibility (EMC)
International
IEC 61326-1: Basic Electromagnetic Environment
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
USA (FCC)
47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Functions
CP States
A, B, C, D
CP Error "E"
On/off
PE Error
On/off
GFCI Test
Yes, test resistor of 2 kΩ connected between L1 and PE, time limitation 40 ms
PE Pre-Test (typical)
Visible indication >30 V on PE conductor
Outputs (for test purpose only)
Measuring terminals
Max. 250 V 50/60 Hz, CAT II 250 V
L1, L2/N, PE
CP signal output terminals
Approx. ±12 V (under normal conditions), in case of wrong wiring or error of the charging station these terminals can be hazardous ≥ max. 250 V against PE