Single-port, simultaneous dual-wavelength feature completes testing in half the time and saves measurements from both wavelengths into one record
CheckActive feature emits an audible tone and displays an icon when a live fiber is detected, eliminating the need to set up a measurement
FindFiber Remote ID enables one individual to quickly identify cable connections or routings (especially useful at patch panels), eliminating the need for multiple technicians on opposite ends of a fiber link to match color combinations
Min/Max capability automates precision tracking of intermittent power fluctuations
Large internal memory save 1000 results which enables continuous testing and recording
LinkWare Cable Test Management software helps to analyze test results and create professional test reports
1 Conforms to relevant European Union directives; Conforms to relevant Australian standards; Listed by the Canadian Standards Association; Complies with 21CFR.1040.10,11, and EN60825-1, 2:2007 (Class 1, Hazard Level 1)
Removable adapter, SC adapter as default, optional adapters include LC, ST
Display update rate
1 reading per second
Reference
Individually set for each wavelength
FindFiber ID detection
Yes
Power Requirement
2 AA Alkaline batteries
Battery Life4
> 50 Hours (typical)
Automatic Power Off
10, 20, 30 or 60 minutes (can be disabled by user)
Low Battery Warning
Yes, low battery icon blinks
Size (L x W x H)
6.4 in x 3.2 in x 1.5 in (16.5 cm x 8.0.cm x 3.9 cm)
Weight
11.5 oz (325 grams)
1 For 850nm, ±0.2 dB for power from 0 to -45 dBm, ±0.25 dB for power < -45 dBm 2 ±0.1dB for power from 0 to -55 dBm, ±0.2 dB for power > 0 dBm and < -55 dBm 3 23°C ±2°C, power level -20dBm, continuous wave, 62.5/125µm at multi mode wavelengths, 9/125 µm at 1310,1490, 1550 and 1625 nm; add 0.1 dB for 1625 nm, 4 For measured power levels 0 dBm or less, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.
Multimode Optical Source
Emitter Type
LED
Central Wavelength
850 nm, 1300 nm
Wavelength Accuracy
850 nm: +/-30 nm
1300 nm: +/- 20 nm
Spectral Width (FWHM)
850 nm: 50 nm (typical)
1300 nm: 135 nm (typical)
Minimum Output Power
850/1300 nm: ³ -20 dBm
Power Output Stability1
±0.1 dB over 8 hours
Auto Dual-Wavelength Switching
Yes. Can be enabled/disabled by user.
Optical Output Connector
Fixed SC
FindFiber Code Generation
Yes. Fixed at ID 1.
Modes
CW, 2 kHz modulated, Auto-wavelength
Power Requirement
2 AA Alkaline batteries.
Battery Life2
40 hrs (typical)
Automatic Power Off
30 minutes (can be disabled by user)
Low Battery Warning
Yes, LED blinks
Size (L x W x H)
5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm)
Weight
1.8 oz (278 g)
1 23° C ± 2° C, after 5 minutes warm-up time 2 In auto-wavelength mode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.
1310/1550 source is fixed at ID 2
1490 nm/1625 nm is fixed at ID 3.
Modes
CW, 2 kHz modulated, Auto-wavelength
Power Requirement
2 AA Alkaline batteries
Battery Life2
30 hrs (typical)
Automatic Power Off
30 minutes (can be enabled or disabled by user)
Low Battery Warning
LED blinks.
Size (L x W x H)
5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm)
Weight
9.8 oz (278 grams)
1 23° C ± 2° C, after 5 minutes warm-up time 2 In auto-wavelength mode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.
FindFiber Source Specifications
Emitter Type
Laser
Source Connector
Fixed SC
FindFiber Code Generation
1 through 8. Default is 3.
Power On/Low-battery Indicator
LED
Power Requirement
2 AA Alkaline batteries
Battery Life
> 80 Hours (typical)
Automatic Power Off
30 minutes
Low Battery Warning
LED blinks
Size (L x W x H)
7.1 in x 1.3 in x 1.0 in (17.9 cm x 3.2 cm x 2.5 cm)