Order #: 1529T-4TC
Mfg #: 1672235
Fluke Calibration 1529-T-156 Chub-E4 Thermometer, 4 TC Inputs
Order #: 1529T-4TC
Mfg #: 1672235
Product Highlights
- Four channels for PRTs, thermistors, and thermocouples
- Displays eight user-selected data fields from any channel
- Logs up to 8,000 readings with date and time stamps
- Battery provides eight hours of continuous operation
Inputs
The Chub-E4 has four inputs for reading four different sensors simultaneously, and we’ll configure those inputs in any of three different ways according to your preference. Choose four channels of thermocouple inputs, four channels of PRT/thermistor inputs, or two channels of each. With this thermometer, reading thermocouples, PRTs, and thermistors accurately from the same device is no problem.100-ohm, 25-ohm, or 10-ohm PRTs and RTDs are read using ITS-90, IEC-751 (DIN), or Callendar-Van Dusen conversion methods. Typical accuracies include ±0.004 °C at –100 °C and ±0.009 °C at 100 °C. Thermistor readings are converted using the Steinhart-Hart polynomial or standard YSI-400 curve and are as accurate as ±0.0025 °C at 25 °C with resolution of 0.0001 °.
Thermocouple inputs read all the common thermocouple types, including B, E, J, K, N, R, S, T, and Au-Pt, and allow you to choose between internal and external reference junction compensation. Typical accuracy for a type J thermocouple at 600 °C is ±0.35 °C using internal reference junction compensation and not including the thermocouple. (Support for C and U type thermocouples is available. Download the application note Using Fluke Calibration Readouts with Tungsten-Rhenium and other Thermocouples.)
PRTs and thermistors connect easily to the 1529 using Fluke Calibration’s patented mini DWF connectors, which accept bare wire, spade lug, or mini banana plug terminations. Thermocouples connect using standard or miniature terminations. Measurements are taken each second and can be taken simultaneously or sequentially. A special high-speed mode allows measurements on one channel to be taken at the rate of 10 per second.
Display
If you think three sensor types and four inputs sounds versatile, wait until you see the display panel on the Chub-E4. Displaying measurements in °C, °F, K, ohms, or millivolts and choosing temperature resolution from 0.01 to 0.0001 are just the beginning.
You can also select any eight items from our long list of displayable data fields to view on-screen. Choose statistical functions such as averages, standard deviations, and spreads; choose probe information such as probe type and serial number; choose T1–T2 functions using inputs from any two channels; or choose utility functions such as the date, time, and battery power level. You can even save up to 10 screen configurations for easy recall.
The push of a single front-panel button also brings up a simple menu system to easily guide you through all the internal setup and memory options of the 1529. Probe coefficients, sample intervals, communication settings, password settings, and a host of other functions are all easily accessible.
Communications
The memory and communications capabilities of the Chub-E4 make it perfect for benchtop thermometry, on-site measurements, lab calibration work, and remote data logging. Optional software packages from Fluke make this one of the most powerful thermometers on the market.With battery power and memory to store up to 8,000 measurements (including date and time stamps) at user-selected intervals, the 1529 has plenty of data logging capability. Store 100 individual measurements or any number of automatic log sessions (up to 8,000 readings), each tagged with an identifying session label. Fourteen different logging intervals may be selected, from 0.1 second to 60 minutes.
With Fluke Calibration’s 9935 LogWare II (page 85), data may be quickly downloaded to your PC for complete graphical and statistical analysis. Separate log sessions may even be automatically downloaded to separate files based on session labels. With this software, the 1529 can even be used for real-time data logging. Log four channels at once directly to your PC with virtually no limit to the number of data points you take. You can analyze data, set alarm events, and even set delayed start and stop times.
With MET/TEMP II software, the Chub-E4 may be integrated into a completely automated calibration system. Use one input for your reference thermometer and calibrate up to three other thermometers automatically (see page 81). An RS-232 port is standard on every unit. An IEEE-488 port is optional.
More great features
Did we forget some aspect of versatility on this thermometer? No!
The 1529 runs on AC power from 100 to 240 volts, DC power from 12 to 16 volts, or off its internal nickel-metal-hydride battery for eight hours between charging. The standard battery charges in less than three hours and lasts through 500 charge/recharge cycles.
If you want to rack-mount your Chub-E4, we’ve even got a rack-mount kit for you. This unit fits on your benchtop, in your instrument rack, and even in your hand.
Of course, all the reference thermometers you might need for your 1529 are available from Fluke, including secondary standard PRTs, standard thermistors, and noble-metal thermocouples. Carrying cases and even a serial printer for direct printer output are also available.
We’ve said it before and we’ll keep saying it: Fluke Calibration simply makes the best thermometer readouts in the world. No one else gives you a comparable combination of accuracy, versatility, productivity-enhancing features, and price. No one. Get a Chub-E4 and just enjoy everything it’ll do for you. You’ll love it.
- Fluke Calibration 9935-S LogWare Software II, 2 +/- Channel, Single UserLogWare Software II, 2 +/- Channel, Single User
Order #: 9935-S
Mfg #: 1658767
Availability: Call for availability$1,250.00 - Fluke Calibration 2506-1529 IEEE Interface Option for 1529 Chub-E4 Standards ThermometerIEEE Interface Option for 1529 Chub-E4 Standards Thermometer
Order #: 2506-1529
Mfg #: 1650702
Availability: Ships in 3-4 weeks$869.00 - Fluke Calibration 9935-M LogWare for Multichannel Thermometers - MultiuserLogWare for Multichannel Thermometers - Multiuser
Order #: 9935-M
Mfg #: 1658759
Availability: Ships in 2-3 weeks$1,800.00 - Fluke Calibration 2362-156 Spare AC Adapter, 15V (1529) 110VSpare AC Adapter, 15V (1529) 110V
Order #: 2362-156
Mfg #: 2085452
Availability: Ships in 3-4 weeksSpecial Price $278.05 Regular Price $335.00 - Fluke Calibration 9326 Rugged Carrying Case for 1529 &12" ProbeRugged Carrying Case for 1529 &12"Probe
Order #: 1529T-CS
Mfg #: 1658685
Availability: Ships in 3-4 weeksSpecial Price $597.60 Regular Price $720.00
-