The Solar 9354-1 Transient Generator was specifically engineered for pulse susceptibility testing on subsystems and equipment. With various accessories, including reactive networks and coupling devices, loop antennas, parallel plates, and TEM cells, the generated output may be altered and applied to other specifications.
Features and Specifications of the Solar 9354-1 Transient Generator include:
Panel-mounted digital voltmeter monitors the adjusted open circuit discharge voltage
Pulse rates up to one pulse per second maximum
Single pulse feature enables controlled isolation of transient effects
Output voltage ajustable from 0.1% to 100% of selected discharge voltage
Applications:
Susceptibility tests in accordance with MIL-STD-461E/F/G, Method CS116
Limited testing for RTCA DO-160D, Section 22
Specifications of the Solar 9354-1 Transient Generator:
Damped Sinusoid Pulses:
10 kHz:
Open circuit voltage: 30 V
Calculated short circuit current: 120 A
Source impedance:
100 kHz:
Open circuit voltage: 300 V
Calculated short circuit current: 120A
Source impedance:
1 MHz:
Open circuit voltage: 3200 V/div>
Calculated short circuit current: 128A
Source impedance:
10 MHz:
Open circuit voltage: 3200 V
Calculated short circuit current: 128 A
Source impedance:
30 MHz:
Open circuit voltage: 1000 V
Calculated short circuit current: 20 A
Source impedance:
100 MHz:
Open circuit voltage: 300 V
Calculated short circuit current 6 A
Source impedance:
DO-160E/F/G test levels possible from model 9354-1 applications: