Order #: BT2152B-032-RENT2
Mfg #: BT2152B-032-RENT2
Keysight BT2152B-032 for Rent, Li-Ion Battery Self Discharge Analyzer, 0.5 to 4.5V, 32-Channel
Order #: BT2152B-032-RENT2
Mfg #: BT2152B-032-RENT2
Request a Rental Quote
Have a Question? Speak to a Transcat Rental Expert: 800.264.4059
Product Highlights
The BT2152B Self-Discharge Analyzer measures self-discharge current of Li-Ion cells providing a revolutionary reduction in the time required to discern good vs bad cell self-discharge performance, and dramatic reductions in cell manufacturing WIP
- Up to 32 channels of self-discharge current measurement available in 4-channel increments
- Cell voltage range: 0.5 to +4.5 V
- Current measurement accuracy: ± (0.30% + 250 nA)
- Voltage measurement accuracy: ± (0.04% + 0.1 mV)
- Voltage sourcing stability: ± 3 µV peak (24 hour), ± 0.85 µV peak (1 minute)
- Current measurement range: ± 10 mA
The Keysight BT2152B Self-Discharge Analyzer directly measures self-discharge current of Li-Ion cells. The analyzer provides a revolutionary reduction in the time required to discern good vs. bad cell self-discharge performance. This drives dramatic reductions in Work-in-Process inventory, working capital costs, and facility costs for cell manufacturers.
The Self-Discharge Analyzer accurately measures cell self-discharge current and cell voltage. Depending on the characteristics of the cells, measurements are directly made in minutes or hours instead of taking days or weeks using open-circuit cell voltage measurements to indicate which cells are good vs. bad.
The Self-Discharge Analyzer quickly measures self-discharge current using a precision potentiostatic measurement method with the characteristics needed to accurately make the current measurement:
- Minimum disturbance of the cell
- The voltage applied to the cell is quickly matched to the actual cell voltage. This minimizes any new charge or discharge and thus limits any new RC settling to a minimum.
- The voltage applied to the cell is very stable (± 3 µVpk) to minimize continuing charge-discharge current noise on the self-discharge current measurement.
- Accurately measures low-level self-discharge currents to ±(0.30% + 250 nA)
Process Improvements and Cost Savings in Self-Discharge Testing
Li-Ion cell manufacturers keep far greater numbers of cells in work-in-process inventory than they would like because of the time they are required to keep their cells in the aging process.
Today, most of the total aging time is often caused by the time required to determine if the cells' self-discharge behavior is within acceptable limits. This large time period is driven by how long it takes for the change-in-OCV (ΔOCV) measurement. Reducing the amount of time cells spend in the aging step as work-in-process inventory provides savings that flow directly to the bottom line.
Improvements in the aging process and resulting cost savings from directly measuring self-discharge current can be seen by examining a typical model of the formation and aging process in cell manufacturing, and comparing the traditional OCV method vs. directly measuring self-discharge current of the cells.
Traditional ΔOCV Method
Determining good vs. bad self-discharge performance is based on a 2-step process. In the first step, the cells which are clearly good and clearly bad are separated from "suspect" cells by a ΔOCV test done after the 5-day aging period, where ΔOCV = (OCV2
-
Keysight / Agilent B2912B for Rent, Precision Source/Measure Unit, 2 channel, 10fA resolution, 210VPrecision Source/Measure Unit, 2ch, 10fA resolution, 210VCall for price
-
Keysight / Agilent N1268A for Rent, Ultra High Voltage ExpanderUltra High Voltage ExpanderCall for price
-
Keysight SL1049A-201 for Rent, EV charging adapter, 32 A Type 1 AC, SAE J1772, IEC 62196-2EV charging adapter 32 A Type 1 AC, SAE J1772, IEC 62196-2Call for price
-
-
NH Research 9200-4912-36 for Rent, High-Power Battery Test System, 120V/200A/36kWHigh-Power Battery Test System 120V/200A/36kWCall for price
-
Chroma 61815 for Rent, Regenerative Grid Simulator, 15 kVARegenerative Grid Simulator, 15 kVACall for price
-
Fluke FEV100 for Rent, Test adapter for EV charging stations with type 1 connect & cableTest adapter EV charging stations w/type 1 connect&cableCall for price
-
Keysight RP7984A for Rent, DC Power Supply, Birectional, PV Mode, 1500 V, 60A, 30 kWDC Power Supply, Birectional, PV Mode, 1500 V, 60A, 30 kWCall for price
-
NH Research 4600-3 for Rent, Programmable AC Electronic Loads, 3KW AC Load with 120v inputProgrammable AC Electronic Loads 3KW AC Load w/ 120v inputCall for price
-
Keysight / Agilent N1265A for Rent, Ultra High Current Expander/FixtureUltra High Current Expander/FixtureCall for price
-
Elektro-Automatik PSB12000-40 for Rent, DC Power Supply, Bidirectional, 2000V, 40A, 30 kWDC Power Supply, Bidirectional, 2000V, 40A, 30 kWCall for price
-
Rent the NH Research 9300-100 High-Voltage Battery Test System, 100kw, 600v or 1200vHigh-Voltage Battery Test System, 100kw, 600v or 1200vCall for price
-
Keysight SL1049A-203 for Rent, EV charging adapter, 1000V, 200A Type 1 CCS DC, IEC 62196-3EV charging adapter 1000V, 200A Type 1 CCS DC, IEC 62196-3Call for price
-
Keysight SL1040A for Rent, Scienlab Portable Charging Discovery System, HV, 301 COMScienlab Portable Charging Discovery System, HV, 301 COMCall for price
-
Keysight SL1049A-106 for Rent, Plug-in (Female Receptacle) for EVSE emulation (Advanced)Plug-in (Female Receptacle) for EVSE emulation (Advanced)Call for price
-
Keysight SL1049A-108 for Rent, EVSE plug-in CCS Type 1 AC/DC, High Current, IEC 62196-2/3EVSE plug-in CCS Type 1 AC/DC, High Current, IEC 62196-2/3Call for price
-
NH Research 9410-12 for Rent, Regenerative Grid SimmulatorRegenerative Grid SimmulatorCall for price
-
Keysight SL1049A-219 for Rent, Cable + Plug Adapter for EV/EVSE Emulation for RP79XXCable + Plug Adapter for EV/EVSE Emulation for RP79XXCall for price