Used Hioki MR8847A HiCorder Multifunction Data Logger, 512MW, Main Unit
HiCorder Multifunction Data Logger 512MW Main Unit
Order #: MR8847-53-USED
Mfg #: MR8847-53
Call for price
Call for price
Used Hioki MR8847A HiCorder Multifunction Data Logger, 512MW, Main Unit
HiCorder Multifunction Data Logger 512MW Main Unit
Order #: MR8847-53-USED
Mfg #: MR8847-53
Call for price
Call for price
Availability:
In stock
This item is available as RENTAL at
Call for price
Shop now
Product Highlights
Hioki Memory HiCorders are high-speed waveform monitoring and recording devices that can simultaneously measure multiple physical phenomena such as voltage, current, temperature, vibration, acceleration and rotation due to complete isolation between channels and from each channel to the ground
- Supports a wide variety of measurements with a total of 13 plug-in modules (5 new modules added)
- Generate and record with a single unit
- Direct 1000 V high voltage input testing
- High-speed sampling up to 20MS/s with fully isolated inputs
- 16 analog + 16 logic channels to 64 logic + 10 analog channels
- High-speed sampling with waveform judgement function
- Soil-resistant construction strong against adverse working environments
- Big buttons coated to withstand industrial oil and residue
- Drop-in paper loading and one-touch setup, along with high-speed 50mm/s printing
- Number of channels:
- [8 analog input modules]: 16 analog channels + 16 logic channels (standard)
- [5 analog input modules + 3 logic input modules]: 10 analog channels + 64 logic channels (standard 16 channels + 48 channels in logic input modules)
- * For analog modules, channels are insulated vs. each other and vs. unit ground. For logic modules and integrated standard logic channels, all channels use the unit ground.
- Measurement ranges (20 div full-scale):
- 5 mV to 20 V/div, 12 ranges, resolution : 1/100 of range (using the 8966)
- 5 mV to 50 V/div, 5 ranges, resolution : 1/1 000 000 of range (using the MR8990)
- 200 mV to 50 V/div, 8 ranges, resolution : 1/1600 of range (using the U8794)
- Max. allowable input: 400 V DC (using the 8966/8968), 500 V DC (using the MR8990), 1000 V DC (using the U8974)
- Frequency characteristics (-3dB): DC to 5 MHz (using the 8966), DC (using the MR8990), DC to 100 kHz (using the U8794)
- Time axis (Memory function): 5 µs to 5 min/div (100 samples/div) 26 ranges, External sampling (100 samples/div, or free setting), Time axis zoom: x2 to x10 in 3 stages, compression: 1/2 to 1/200 000 in 16 stages
- Measurement functions: MEMORY (high-speed recording), RECORDER (real-time recording), X-Y RECORDER (X-Y real-time recording), FFT
- Other functions: Waveform judgment (at Memory or FFT function)
- Memory capacity:
- Total 512 M-words (Memory expansion: none)
- 256 MW/ch (using 2 Analog channels), to 32 MW/ch (using 16 Analog channels)
- Removable storage: CF card slot (standard) x1 (up to 2GB, FAT, or FAT-32 format), SSD (128 GB, optional), USB memory stick (USB 2.0)
- Printing: 216 mm (8.50 in) x 30 m (98.43 ft), thermal paper roll, Recording speed : Max. 50 mm (1.97 in)/s
- Display: 10.4 inch TFT color LCD (SVGA, 800 x 600 dots)
- Displayable languages: English, Japanese, Korean, Chinese
- External interfaces: [LAN] 100BASE-TX (FTP server, HTTP server), [USB] USB2.0 compliant, series A receptacle x1, series B receptacle x1, (File transfer internal drive/CF card to PC, or remote control from PC)
- Power supply:
- 100 to 240 V AC, 50/60 Hz (130 VA max., when using printer: 220 VA max.)
- 10 to 28 V DC (when using the optional factory-installed DC power unit 9784)
- Dimensions and mass: 351 mm (13.82 in) W x 261 mm (10.28 in) H x 140 mm (5.51 in) D, 7.6 kg (268.1 oz) (main unit only)