Fluke 754/750SW BU Fluke 754 DPC & 750SW DPCTRACK2 Software Bundle Package
Fluke 754 DPC & 750SW DPCTRACK2 Bundle Package
Order #: FLUKE-754/750SW BU
Mfg #: 4465547
This product is available for shipping to the United States, Canada, and Puerto Rico only.
Overview
You're going to love what we've done with your calibrator.
The 754 is everything you needed and wished for in the 744 and more! HART communication capability is combined to deliver an integrated communicating calibrator. This rugged, reliable tool is ideal for calibrating, maintaining, and troubleshooting HART and other instrumentation.
The 754 does the work of several tools - sourcing, simulating and measuring pressure, temperature, and electrical signals in one rugged, hand-held device. You'll fall in love with the new improved graphical screen, Li-Ion battery for longer life, USB port and new accessories to complete the package.
For documentation, the 754 automates calibration procedures and captures your data. And, of course, it helps you meet rigorous standards like ISO 9000, FDA, EPA and OSHA regulations.
HART Capabilities
The 754 is designed to take on nearly all the day-to-day tasks you now perform with a separate communicator. In fact, it offers most of the communication capabilities of a HART communicator.
Product Highlights
Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters
Power transmitters during test using loop supply with simultaneous mA measurement
Measure/source pressure using any of 29 Fluke pressure modules
Advanced features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay and more
Includes HART communication for adjusting and testing HART smart transmitters.
Includes the new C799 Field soft case
Three-year warranty
Each Unit Includes
DPC/TRACK2 Software
Three sets of stackable test leads
Three sets of TP220 test probes with three sets of “extended tooth” alligator clips
Two sets AC280 hook clips
BP7240 Li-ion battery pack
BC7240 battery charger
C799 field soft case
USB communication cable
Getting started guide
Instruction manual on CDROM
NIST traceable certificate of calibration
HART communication cable
Webinars
Automating and Documenting Temperature Calibration Webinar with Fluke Calibration
$1,713.99
$1,913.99
Special Price
$612.31
Regular Price
$687.99
$1,080.99
Special Price
$240.29
Regular Price
$269.99
$324.99
Special Price
$129.04
Regular Price
$144.99
Special Price
$95.22
Regular Price
$106.99
Special Price
$27.58
Regular Price
$30.99
Special Price
$57.84
Regular Price
$64.99
Range/Resolution
1 Year
2 Years
Voltage DC
100.000 mV
0.02% + 0.005 mV
0.03% + 0.005 mV
3.00000 V
0.02% + 0.00005 V
0.03% + 0.00005 V
30.0000 V
0.02% + 0.0005 V
0.03% + 0.0005 V
300.00 V
0.05% + 0.05 V
0.07% + 0.05 V
Voltage AC
3.000 V (40 Hz to 500 Hz) / 0.001 V
0.5% + 0.002 V
1.0% + 0.004 V
30.00 V (40 Hz to 500 Hz) / 0.01 V
0.5% + 0.02 V
1.0% + 0.04 V
300.0 V (40 Hz to 500 Hz) / 0.1 V
0.5% + 0.2 V
1.0% + 0.2 V
Current DC
30.000 mA
0.01% + 5 uA
0.015% + 7 uA
110.00 mA
0.01% + 20 uA
0.015% + 30 uA
Resistance
10.000 Ω
0.05% + 50 mΩ
0.07% + 70 mΩ
100.00 Ω
0.05% + 50 mΩ
0.07% + 70 mΩ
1.0000 kΩ
0.05% + 500 mΩ
0.07% + 0.5 Ω
10.000 kΩ
0.1% + 10 Ω
0.15% + 15 Ω
Frequency
1.00 to 110.00 Hz / 0.01 Hz
0.05 Hz
110.1 to 1100.0 Hz / 0.1 Hz
0.5 Hz
1.101 to 11.000 kHz / 0.001 kHz
0.005 kHz
11.01 to 50.00 kHz / 0.01 kHz
0.05 kHz
1 Year
2 Years
Voltage DC
100.000 mV
0.01% + 0.005 mV
0.015% + 0.005 mV
1.00000 V
0.01% + 0.00005 V
0.015% + 0.0005 V
15.0000 V
0.01% + 0.0005 V
0.015% + 0.0005 V
Current DC
22.000 mA (source)
0.01% + 0.003 mA
0.02% + 0.003 mA
Current sink (simulate)
0.02% + 0.007 mA
0.04% + 0.007 mA
Resistance
10.000 Ω
0.01% + 10 mΩ
0.015% + 15 mΩ
100.00 Ω
0.01% + 20 mΩ
0.015% + 30 mΩ
1.0000 kΩ
0.02% + 0.2 Ω
0.03% + 0.3 Ω
10.000 kΩ
0.02% + 3 Ω
0.03% + 5 Ω
Frequency
0.1 to 10.99 Hz
0.01 Hz
0.01 to 10.99 Hz
0.01 Hz
11.00 to 109.99 Hz
0.1 Hz
110.0 to 1099.9 Hz
0.1 Hz
1.100 to 21.999 kHz
0.002 kHz
22.000 to 50.000 kHz
0.005 kHz
Data log functions
Measure functions
Voltage, current, resistance, frequency, temperature, pressure
Reading rate
1, 2, 5, 10, 20, 30, or 60 readings/minute
Maximum record length
8000 readings (7980 for 30 or 60 readings/minute)
Ramp functions
Source functions
Voltage, current, resistance, frequency, temperature
Rate
4 steps/second
Trip detect
Continuity or voltage (continuity detection not available when sourcing current)
Loop power function
Voltage
Selectable, 26 V
Accuracy
10%, 18 V minimum at 22 mA
Maximum current
25 mA, short circuit protected
Maximum input voltage
50 V DC
Step functions
Source functions
Voltage, current, resistance, frequency, temperature
Manual step
Selectable step, change with arrow buttons
Autostep
Fully programmable for function, start delay, stepvalue, time per step, repeat
Operating temperature
-10°C to +50°C
Storage temperature
-20°C to +60°C
Dust/water resistance
Meets IP52, IEC 529
Operating altitude
3000 m above mean sea level (9842 ft)
Agency approvals
CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993
Size
136 x 245 x 63 mm (5.4 x 9.6 x 2.5 in)
Weight
1.2 kg (2.7 lb)
Batteries
Internal Battery Pack Li-ion: 7.2V,4400mAh, 30 Wh
Battery life
>8 hours typical
Battery replacement
Replace without opening calibrator; no tools required
Side port connections
Pressure module connector
USB Connector to interface to your PC
Digital instrument (HART) connector
Connection for optional battery charger/eliminator
Data storage capacity
1 week of calibration procedures results
90 day specifications
The standard specification interval for the 750 Seriesare 1 and 2 years.
Typical 90 day measurement and source accuracy can be estimated by dividing the one year "% of reading" or "% of output" specifications by 2.
Floor specifications, expressed as "% of full scale" or "counts" or "ohms" remain constant.
Degrees or % of reading - Type (α)
Range °C
Measure °C1
1 year
2 year
100 Ω Pt (385)
-200 to 100
0.07°C
0.14°C
100 to 800
0.02% + 0.05°C
0.04% + 0.10°C
200 Ω Pt (385)
-200 to 100
0.07°C
0.14°C
100 to 630
0.02% + 0.05°C
0.04% + 0.10°C
500 Ω Pt (385)
-200 to 100
0.07°C
0.14°C
100 to 630
0.02% + 0.05°C
0.04% + 0.10°C
1000 Ω Pt (385)
-200 to 100
0.07°C
0.14°C
100 to 630
0.02% + 0.05°C
0.04% + 0.10°C
100 Ω Pt (3916)
-200 to 100
0.07°C
0.14°C
100 to 630
0.02% + 0.05°C
0.04% + 0.10°C
100 Ω Pt (3926)
-200 to 100
0.08°C
0.16°C
100 to 630
0.02% + 0.06°C
0.04% + 0.12°C
10 Ω Cu (427)
-100 to 260
0.2°C
0.4°C
120 Ω Ni (672)
-80 to 260
0.1°C
0.2°C
Source current
Source °C
Allowable current2
1 year
2 year
1 mA
0.05°C
0.10°C
0.1 mA to 10 mA
0.0125% + 0.04°C
0.025% + 0.08°C
500 μA
0.06°C
0.12°C
0.1 mA to 1 mA
0.017% + 0.05°C
0.034% + 0.10°C
250 μA
0.06°C
0.12°C
0.1 mA to 1 mA
0.017% + 0.05°C
0.034% + 0.10°C
150 μA
0.06 C
0.12 C
0.1 mA to 1 mA
0.017% + 0.05°C
0.034% + 0.10°C
1 mA
0.05°C
0.10°C
0.1 mA to 10 mA
0.0125% + 0.04°C
0.025% + 0.08°C
1 mA
0.05°C
0.10°C
0.1 mA to 10 mA
0.0125% + 0.04°C
0.025% + 0.08°C
3 mA
0.2°C
0.4°C
0.1 mA to 10 mA
1 mA
0.04°C
0.08°C
0.1 mA to 10 mA
1. For two and three-wire RTD measurements, add 0.4°C to the specifications.
2. Supports pulsed transmitters and PLCs with pulse times as short as 1 ms
Type
Source °C
Measure °C
Source °C
1 year
2 years
1 year
2 years
E
-250 to -200
1.3
2
0.6
0.9
-200 to -100
0.5
0.8
0.3
0.4
-100 to 600
0.3
0.4
0.3
0.4
600 to 1000
0.4
0.6
0.2
0.3
N
-200 to -100
1.0
1.5
0.6
0.9
-100 to 900
0.5
0.8
0.5
0.8
900 to 1300
0.6
0.9
0.3
0.4
J
-210 to -100
0.6
0.9
0.3
0.4
-100 to 800
0.3
0.4
0.2
0.3
800 to 1200
0.5
0.8
0.3
0.3
K
-200 to -100
0.7
1
0.4
0.6
-100 to 400
0.3
0.4
0.3
0.4
400 to 1200
0.5
0.8
0.3
0.4
1200 to 1372
0.7
1
0.3
0.4
T
-250 to -200
1.7
2.5
0.9
1.4
-200 to 0
0.6
0.9
0.4
0.6
0 to 400
0.3
0.4
0.3
0.4
B
600 to 800
1.3
2
1
1.5
800 to 1000
1
1.5
0.8
1.2
1000 to 1820
0.9
1.3
0.8
1.2
R
-20 to 0
2.3
2.8
1.2
1.8
0 to 100
1.5
2.2
1.1
1.7
100 to 1767
1
1.5
0.9
1.4
S
-20 to 0
2.3
2.8
1.2
1.8
0 to 200
1.5
2.1
1.1
1.7
200 to 1400
0.9
1.4
0.9
1.4
1400 to 1767
1.1
1.7
1
1.5
C
0 to 800
0.6
0.9
0.6
0.9
800 to 1200
0.8
1.2
0.7
1
1200 to 1800
1.1
1.6
0.9
1.4
1800 to 2316
2
3
1.3
2
L
-200 to -100
0.6
0.9
0.3
0.4
-100 to 800
0.3
0.4
0.2
0.3
800 to 900
0.5
0.8
0.2
0.3
U
-200 to 0
0.6
0.9
0.4
0.6
0 to 600
0.3
0.4
0.3
0.4
BP
0 to 1000
1
1.5
0.4
0.6
1000 to 2000
1.6
2.4
0.6
0.9
2000 to 2500
2
3
0.8
1.2
XK
-200 to 300
0.2
0.3
0.2
0.5
300 to 800
0.4
0.6
0.3
0.6